Electrolux EK 5741 Electric Pressure Cooker User Manual


 
19
Electrical connections
Any electrical work required to install
this hob should be carried out by a
qualified electrician or competent
person, in accordance with the current
regulations.
THIS COOKER MUST BE EARTHED.
The manufacturer declines any liability
should these safety measures not be
observed.
This cooker is designed to be connected to a
230-240V 50Hz AC electrical supply.
Before switching on, make sure the electricity
supply voltage is the same as that indicated on
the hob rating plate. The rating plate is located on
the bottom of the hob. A copy is attached on the
back cover of this book.
The cooker is supplied without supply cord. A 3
core flexible supply cord must be fitted, in
accordance with the specification given in the
relevant tables.
1) Loosen the two fixing screws securing the
back protective screen of the cooker, then
lift it up and remove it. This will expose
the terminal block on the right bottom
corner.
2) Loosen the two cable clamp screws and
lift the top section of the clamp enough to
allow the cable to be passed through.
3) Connect the red (live) wire to the terminal
which is marked with the letter "L".
4) Connect the black (neutral) wire to the
terminal which is marked with the letter
"N".
5) After fitting a green or yellow/green sleeve
over the bare copper wire (earth wire),
connect the exposed end to the terminal
which is marked with the earth symbol
or with the letter "E"coloured green and
yellow.
NOTE:
The earth wire should be about 2 cm.
longer than the live and neutral wires.
6) Secure the cable by means of the clamp
screws and refit the back protective
screen.
The cooker should be connected to a double
pole switch with a minimum gap of 3 mm.
between the switch contacts and of a type
suitable for the required load in compliance with
the current electric regulations. The switch
should be sited within 2m of the hob and be
easily accessible upon completion of the
installation.
The switch must not break the yellow and green
earth cable at any point.
Ensure that the hob supply cord
does not come into contact with
surfaces with temperatures higher
than 50 deg. C.
FO 2375
Supply Cable Specifications
Connection Min. size Cable / flexFuse
via Cable/flex type
Cooker 3 x 6 mm
2
H05 VV-F 30 A
Control
Circuit
For Uk use only
For Europe use only
Min.size Cable/flex Cable / flex type Fuse
3x 2.5 mm
2
H05 RR-F 30 A
F