Electrolux ERC3711WS Beverage Dispenser User Manual


 
8
Electrolux 818 35 40-00/7
To change the light bulb
Before replacing the light bulb, disconnect the power
plug from the outlet.
Fold the grille backward by unsnapping the front
edge.
Use a bulb of the same type, E14 socket, maximum
ratingof15W.
When the appliance is not in use
Disconnect the appliance from electricity supply.
Empty all foods and clean the appliance, leaving the
doors ajar to prevent unpleasant smells.
If the appliance is left on, e.g. while on holiday, ask
somebody to check it once in a while to prevent the
food inside from spoiling in case of a power failure.
Something Not Working
Before contacting your local Service Force Centre check the following points:
Symptom Solution
"" is displayed in the temperature
display.
An error has occurred in measuring the temperature. Call your
service representative. (The cooling system will continue to
keep food products cold, but temperature adjustment will not
be possible.)
It is too warm inside the wine cooler. Set a lower temperature.
Make sure that the door is completely closed and that the
rubber door seal is complete and clean.
It is too cold inside the wine cooler. Set a warmer temperature.
There is water on the cooling plate inside
thewinecooler.
This is normal. During automatic defrosting, frost thaws on the
cooling plate.
Water is running inside the wine cooler. Clean the water drain and drain hole inside the wine cooler
using e.g. cotton swabs or a bottle cleaner brush.
Food products could have been placed near the rear of the
appliance, preventing the water from running into the drain.
Water comes out on the floor. Place the drain hose at the back of the appliance above the
drain bowl. See the chapter "Before use"
The compressor operates continuously. Set a warmer temperature.
Make sure that the door is completely closed and that the
rubber door seal is complete and clean.
The cabinet does not operate at all.
Cooling or interior light does not
operate. No indicator lamps light.
The appliance is not switched on.
Power does not reach the appliance. (Try connecting another
electrical device to the power outlet.)
The fuse has blown.
The power plug is not properly connected.
Noise
Carefully follow the instructions in the
chapter "Installing the cabinet".
The refrigerating system will always produce some sounds. A
pulsing sound is heard when coolant is pumped i nside the
cooling pipes. A ticking sound from the thermostat can be
heard when the compressor switches on and off. The sound
level varies depending on the operation of the cabinet.
If you feel the sound level is incorrect:
Make sure the pipes at the back of the cabinet not touch each
other. Carefully bend them if they do.
If the cushion spacers (between the cabinet wall and pipes)
come loose, put them back in place again.