818 14 00-00/6
43
Technical Terminology
•
Refrigerant
Liquids that can be used to a generate a cooling effect are known as
refrigerants. They have a relatively low boiling-point, indeed so low,
that the warmth from the food stored in the fridge or freezer can
cause the refrigerant to boil and vaporise.
•
Refrigerant Circuit
Closed circulation system that contains the refrigerant. The refri-
gerant circuit comprises primarily of an evaporator, a compressor, a
condenser and pipe work.
•
Evaporator
The refrigerant is evaporated in the evaporator. Similar to all other
liquids, refrigerant requires heat to evaporate. This heat is removed
from the interior of the appliance, as a result the interior is cooled.
The evaporator is therefore located inside the appliance or placed in
foam immediately behind the inner wall and thus not visible.
•
Compressor
The compressor looks like a small drum. It is driven by a built-in elec-
tric motor and is mounted on the base of the appliance at the rear.
The task of the compressor is to draw in vaporised refrigerant from
the evaporator, to compress it, and to pass it on to the condenser.
•
Condenser
The condenser normally has the form of a grid. The refrigerant com-
pressed in the compressor is liquefied in the condenser. During this
process, heat is released to the surrounding air at the surface of the
condenser. The condenser is mounted on the base of the appliance.
Regulations, Standards, Guidelines
This appliance was designed for household use and was manufactured
in accordance with the appropriate standards. The necessary measures
in accordance with appliance safety legislation regulations (GSG), acci-
dent prevention regulations for refrigeration appliances (VBG 20) and
the regulations of the German Society of Electrical Engineers (VDE)
were observed in the manufacture of this appliance.
The refrigerant circuit has been checked for leaks.
;
This appliance is in accordance with the following EU guidelines:
– 73/23/EWG dated 19 February 1973 - low voltage guidelines.
– 89/336/EWG dated 3 May 1989
(including guideline change notice 92/31/EWG) - EMV guideline