40
Installation
INSTALLING THE APPLIANCE
1. Remove all packaging and check carefully for any
signs of damage.
2. If fitting the microwave oven above a conventional
oven (position A) then use the mylar sheet provided.
a. Cut the Mylar sheet to fit the internal width of
the unit.
b. Peel back the protective cover on the tape and fix
to the rear of the shelf
so that it covers
the service
gap. (See
diagram).
3. Fit the appliance into the kitchen cupboard slowly,
and without force, until the front frame of the oven
seals against the front opening of the cupboard.
4. Ensure the appliance is
stable and not leaning.
Ensure that a 5mm gap is
kept between the cupboard
door above and the top of
the frame (see diagram).
5. Fix the oven in position with the
screws provided.
The fixing points are located on
the top and bottom corners of
the oven (see diagram, item 10,
on page 5).
6. It is important to ensure that the installation of this
product conforms to the instructions in this
operation manual and the conventional oven
manufacturer’s installation instructions.
5 mm
Mylar sheet
Conventional
oven
Internal width
Service gap
Position A
Position B
Conventional
oven
The microwave can be fitted in position A or B:
POSITION NICHE SIZE CHIMNEY Gap Between
W D H (min) Cupboard & Ceiling
A 560 x 550 x 450 50 50
B 560 x 500 x 450 40 50
Measurements in (mm)
Chimney Chimney
NOTE: Ensure the bottom of the oven is 85 cm or more above the floor.
1. AG-72D-UK English 22/11/2005 13:40 Page 40