12
Air deector installation
(Recirculating accessories)
Assemble the air deector with the duct cover
bracket with 4 assembly screws provided as
shown.
Measure from the bottom of the air deector to
the bottom of the hood outlet, as shown.
Cut the duct at the measured size.
Uninstall the air deector removing the 4
assembly screws.
Slip the duct onto the bottom of the deector.
Place the assembled deector and duct over the
exhaust outlet from the hood.
Assemble the air deector to the duct cover
bracket with 4 assembly screws provided as
shown.
•
•
•
•
•
•
•
Connecting the ductwork
Install ductwork, making connections in the
direction of airow as illustrated.
Push duct over the exhaust outlet.
Wrap all duct joints and the ange connections
with duct tape for an airtight seal.
Make the same connection in the wall or ceiling
vent exit.
•
•
•
•
Installing the hood
Duct tape
over seam
Airow
Ductwork
hood
Duct tape
over seam
Airow