Electrolux S 75400 KG Refrigerator User Manual


 
9
If it is unavoidable because of furnishing and the appliance has to be stood
near a cooker take these minimum distances into consideration:
In case of gas or electric cooker 3
cm must be left, when it is less
put a 0,5-1 cm non-flam insula-
tion between the two appliances.
In case of oil or coal-fired stove
the distance must be 30 cms
since they give off more heat.
The refrigerator is designed to oper-
ate when it is totally pushed to the
wall.
When placing the refrigerator keep
minimal distances recommended in
figure.
A: placing it under a wall-cupboard
B: placing it freely
Installation of the Carbon Filter
On delivery the carbon filter is in a plastic bag to maintain it's duration and
characteristics. The filter should be placed behind the flap before the appli-
ance is turned on.
1. Pull the flap outwards. (1)
2. Remove the filter from the plastic
bag.
3. Insert the filter in the slot found in
the back of the flap cover (2).
4. Close the flap cover.
During operation, always keep the
air ventilation flap closed.
The filter should be handled care-
fully so fragments do not loosen
from the surface.