Electrolux SANTO 4085-8 KG Refrigerator User Manual


 
40 818 18 12-01/0
If after the above checks there is still a fault, call your local AEG Service
Force Centre.
In-guarantee customers should ensure that the above checks have been
made as the engineer will make a charge if the fault is not a
mechanical or electrical breakdown.
Please note that proof of purchase is required for in-guarantee service
calls.
Technical Terminology
Refrigerant
Liquids that can be used to a generate a cooling effect are known as
refrigerants. They have a relatively low boiling-point, indeed so low,
that the warmth from the food stored in the fridge or freezer can
cause the refrigerant to boil and vaporise.
Refrigerant Circuit
Closed circulation system that contains the refrigerant. The
refrigerant circuit comprises primarily of an evaporator, a compressor,
a condenser and pipe work.
Evaporator
The refrigerant is evaporated in the evaporator. Similar to all other
liquids, refrigerant requires heat to evaporate. This heat is removed
from the interior of the appliance, as a result the interior is cooled.
The evaporator is therefore located inside the appliance or placed in
foam immediately behind the inner wall and thus not visible.
Excessive build up of frost.
If the door seal is not airtight (probably
after reversing the door) apply warm air
to the non sealing area using a hair dryer
set to a gentle heat. (do not use a fan
heater for this purpose). This will make
the rubber more supple and allow it to
revert to its original shape.
Noise Refer to Normal Operating Sounds
The compressor does not start
immediately after changing the
temperature setting.
This is normal, the compressor starts after
a period of time.
Symptom Solution