21
Levelling
The appliance is provided with adjustable small
feet placed in the back and front corners of the
base.
By adjusting the small feet it is possible to
change the height of the appliance so as to
ensure a better levelling with other surfaces and
a uniform distribution of the liquids contained in
pans or pots.
GAS CONNECTIONS
Gas connection must be carried out according to
the rules in force.
Your cooker is delivered adjusted for the kind of
gas stated on the rating plate.
If the appliance is supplied with natural gas and
the pressure for natural gas is 20mbar. The
following methods of connection to the gas
supply must be used:
Left Hand Connection (from front)
Ensure that the rubber hose and power cord are
not in contact with any part of the hatched area
shown in the diagram and that the loop of the
hose when connected is not in contact with the
floor when the appliance is in position.
Right Hand Connection (from front)
Ensure that the rubber hose and power cord not
in contact with any part of the hatched area
shown in the diagram. It will be necessary to fit
the maximum length hose when using this
method.
Rigid Connection
Where it is not possible to make the connection
using a rubber hose, a rigid pipe work connection
must be used.
Recommendations when using an appliance
flexible connector are as follows:
- For NATURAL the gas installation pipes to the
termination point shall comply with:
Specification for installation of low-pressure
gas pipe work of up to 20mm (R1) in domestic
premises (2nd family gas) – BS 6891;
connection
of flexible
hose
power
cord
connection
of flexible
hose
power
cord