FITTING THE HANDLE (OPTIONAL)
Position the handle (M) and the two right (D) and left (S)
supports, as indicated in fig. 1, and secure to the hood
using the screws provided.
CHANGING FROM EXHAUSTING HOOD TO FILTERING
ONE
In order to make this change (possible also after the use
of the exhausting system), demand a set of carbon filters
to your dealer. Active carbon filters are necessary to
depurate the air, that will be released in the room. Filters
are not washable; they cannot be regenerated and have
to be replaced at most every 4 months. The saturation of
the activated charcoal depends on the more or less
prolonged use of the hood, on the type of cooking and on
the regularity of cleaning the grease filter. The filter (C) has
to be applied to the aspirating group, which is inside the
hood hiting the centre of the group with it and turning it of
90 degrees until the stop click is heard to lock it. Remove
the grill (G) to carry out this operation. Close with the
appropriate covers the upper and back air outlets; turn the
small lever (L) from the position (A) to the position (F). In
this way the hood is ready for the filtering function.
USE AND MAINTENANCE
It is recommended to operate the appliance prior to
cooking.
It is recommended to leave the appliance in operation for
15 minutes after cooking is terminated in order to
completely eliminate cooking vapours and odours.
The proper function of the cooker hood is conditioned by
the regularity of the maintenance operations, in particular,
the active carbon filter.
The anti-grease filters capture the grease particles
suspended in the air, and are therefore subject to clogging
according to the frequency of the use of the appliance.
In order to prevent fire hazard, it is recommendable to
clean the filter at a maximum of 2 months by carrying out
the following instructions:
- Remove the filters from the cooker hood and wash them
in a solution of water and neutral liquid detergent, leaving
to soak.
- Rinse thoroughly with warm water and leave to dry.
- The filters may also be washed in the dishwasher.
The aluminium panels may alter in colour after several
washes. This is not cause for customer complaint nor
replacement of panels.
The active carbon filters purify the air that is replaced
in the environment. The filters are not washable nor re-
useable and must be replaced at maximum every four
months. The saturation of the active carbon filter depends
on the frequency of use of the appliance, by the type of
cooking and the regularity of cleaning the anti-grease
filters.
Clean the fan and other surfaces of the cooker hood
regularly using a cloth moistened with denatured alcohol
or non abrasive liquid detergent.
THE MANUFACTURER DECLINES ALL RESPONSIBILITY
FOR EVENTUAL DAMAGES CAUSED BY BREACHING
THE ABOVE WARNINGS.