Emerson UWL Water Dispenser User Manual


 
9
Scalding Hazard: Do not allow
water to boil. May result in
severe burns.
Tank temperature is factory preset
to 200°F, which mixes with cool tap
water to produce an output water
temperature of approx. 110°F.
To reset the tank thermostat
to 200°, turn the indicator one
notch to the right of vertical.
After adjusting, lift faucet handle for 20 seconds for water to
re-heat to the new setting.
To adjust water temperature, turn thermostat
dial on the front of the tank clockwise to
increase temperature or turn counter clockwise
to decrease temperature. Repeat if necessary.
All changes should be minimal.
Regularly inspect the unit for any signs of
leakage. If there are signs of water damage,
immediately remove the unit from service.
To avoid water damage from leakage,
replace all cut, loose or split tubing.
A drain pan, plumbed to an appropriate
drain or outfitted with a leak detector,
should be used in those applications where
any leakage could cause property damage.
PROPERTY DAMAGE
CARE AND USE
Electric Shock Hazard: To prevent electrical shock, disconnect power before
servicing unit. Use only a properly grounded and polarized electric outlet.
approx. 200°
ADJUSTING THE THERMOSTAT
Only use mild cleaners to clean the faucet
and plastic components.
Cleaners with acids, abrasives, alkaline or
organic solvents will result in deterioration
of the plastic components and void the
warranty.
CLEANING THE FAUCET AND TANK
Anytime the hot water faucet is not used for extended
periods of time, unplug and drain unit. If it is below
freezing you will need to unplug the unit and drain it.
Disconnect power from unit.
Turn faucet lever to warm and allow
water to flow until it is cool.
Shut the faucet off at the valve.
Remove drain screw located on bottom
center of water tank and drain the water
into empty pail.
Empty the tank and then reinstall drain
screw onto the bottom of tank, turning
until snug. Do NOT over tighten.
To place back in working order, fill tank
with water and re-connect the plug.
SEASONAL STORAGE/DRAINAGE