Installing Optional CIB-2 Blower
1. Loosen, but do not remove, (4) hex-head screws located on
the exterior, bottom of the appliance.
2. Position the blower assembly at the rear of the appliance.
The blower assembly has (4) keyholes for attachment to the
exterior, bottom of the appliance.
3. Place the large diameter holes in the keyholes over and behind
the (4) hex-head screws that were loosened in Step 1. Push
inward on the blower assembly to lock the keyholes into position
behind the screws. Tighten (4) hex-head screws to secure
blower assembly to exterior, bottom of the appliance.
4. Remove wire channel from rear cover by removing (4) hex-
head screws. Note: If optional blower is being installed during
initial installation of appliance, the wire channel will not be
attached to rear cover. (Refer to Wire Channel Installation,
Page 13)
5. Attach fan control to FLAT, fan control bracket (Part 9A, Page
27) with (2) 6 x 1/4" screws provided in hardware package.
6. Attach fan control with bracket onto the wire channel by using
(2) 8 x 1/4" screws provided in hardware package.
7. Route wires from fan control and ON/OFF/REMOTE switch
within wire channel.
8. When facing the rear of the appliance, align and insert fan
control with bracket into 1 3/8" x 2" opening on the left side
of the rear cover.
9. Attach wire channel to rear cover by using
(4) hex-head screws removed in Step 4.
(Refer to Wire Channel Installation, Page 13)
10. Insert AUTO/OFF/ON switch into rectangular notch on valve
bracket. Be sure to insert AUTO/OFF/ON switch with letters
(words) upright. (See wiring diagram)
11. Attach 1/4" push-on terminal from blue wire on the fan control
to the AUTO (top) tab on the switch.
12. Attach 1/4" push-on terminal from black wire to the OFF
(middle) tab on the switch.
13. Attach 1/4" push-on terminal from white wire on the fan
control to the ON (bottom) tab on the switch.
14. Installation of optional CIB-2 blower is completed.
Fan Control
The fan control is a non-adjustable automatic type. The fan
control will require between 5 and 10 minutes of main burner
operation before the fan control "closes" and activates the blower.
The blower will continue to run between 5 and 10 minutes after
the main burner shuts off, before the fan control "opens" and
deactivates the blower.
OPTIONAL BLOWER INSTALLATION INSTRUCTIONS