6. Reattach the control box and support. Make sure that
the wiring harness is concealed behind the support.
7. Remove the field wiring compartment cover. Feed the
Power Supply Cable through the electrical knockout.
8. Attach the backdraft damper to the proper exhaust open-
ing using two silver screws supplied with the rangehood.
9. Attach the rangehood to the cabinet bottom. The four
key holes slip onto the four screws mounted to the cabinet
bottom. Tighten the screws.
10. Connect the Power Supply Cable to the rangehood.
Attach the White lead of the power supply to the White lead
of the rangehood with a twist-on type wire connector. Attach
the Black lead of the power supply to the Black lead of the
rangehood with a twist-on type wire connector. Connect
the Green (Green and Yellow) ground wire under the Green
grounding screw.
3. For ductless installations, Charcoal Filters are required
and must be installed before the grease filters are replaced.
The charcoal filters attach to both ends of the blower as
indicated in FIGURE 14.
4. Remove the central support and control box by remov-
ing the screws indicated in FIGURE 11. It is not necessary
to remove the blower to perform this operation.
5. Attach the cover behind the exhaust grate with two silver
screws supplied with the rangehood as indicated in FIGURE 12.
11. Replace the field wiring compartment cover. For duct-
less installations, refer to the next section which discusses
ductless installations. Replace the grease filters.
12. Turn the power supply on. Turn on blower and light.
IF THE RANGEHOOD DOES NOT OPERATE:
• Check that the circuit breaker is not tripped or the
house fuse blown.
• Disconnect the power supply and check that the
wiring connections have been made properly.
DUCTLESS INSTALLATIONS
For ductless installations, the blower must be positioned with
the exhaust pointing forward ( so that the exhaust exits from
the front grill ) before attaching the rangehood to the cabinet.
Ductless installations require Charcoal Filters.
1. Remove both grease filters, the central support and the
control box. Remove the two thumb screws on either side of
the blower and remove the blower from the mounting guides
as indicated in FIGURE 11.
2. Rotate the blower 180° so that the exhaust points out
the front of the rangehood. Replace the two thumb screws
and tighten so that the blower is securely fastened inside the
rangehood as indicated in FIGURE 13. Reattach the control
box and central support. Make sure that the wiring harness
is concealed behind the central support.
FIGURE 10
FIGURE 11
FIGURE 12
FIGURE 14