Faber ISOLA Ventilation Hood User Manual


 
Version 09/05 - Page 7
L M V
FIGURE 15
USE AND CARE INFORMATION
This rangehood system is designed to remove smoke, cooking
vapors and odors from the cooktop area.
For Best Results
Start the rangehood several minutes before cooking to develop
proper airflow. Allow the unit to operate for several minutes
after cooking is complete to clear all smoke and odors from
the kitchen.
Rangehood Control Panel
The control panel, located on the right-hand side under the
canopy, is designed to disappear from view when not needed.
To open, press upward on the front edge and release. The
panel will drop into sight. To close, push upward on the bottom
left or right corner of the control panel and it will slide up into
the hood. The position and function of each control button
are indicated in FIGURE 15.
Light On/Off Button ( L )
On/Off switch for the halogen lights. Move the switch to "1"
to turn the light ON and to "0" to turn it OFF.
FIGURE 16
WARRANTY & SERVICE
All Faber products are warranteed against any defect in ma-
terials or workmanship for the original purchaser for a period
of 1 year from the date of original purchase. This warranty
covers labor and replacement parts. The warranty does not
cover consumable parts such as filters and light bulbs. This
warranty does not apply if this product has been subjected to
faulty installation, misuse, or neglect. This warranty excludes
any consequential expense or damage resulting from any
use or malfunction of the product. All implied warranties are
limited to the duration of this warranty.
To obtain warranty service, contact the dealer from whom you
purchased the rangehood, or the local Faber distributor. If you
cannot identify a local Faber distributor, contact us at (508)
358-5353 for the name of a distributor in your area.
WIRING DIAGRAMS
STANDARD INTERNAL BLOWER
*OPTIONAL REMOTE BLOWER
• This rangehood uses 20 watt halogen lamps.
* If a remote blower is used with this rangehood, current
draw must not exceed 4 amps.
Blower Speed Button ( V )
Variable speed control for blower. Move the switch to the far
left for LOW Speed and to the far right for HIGH speed.
Cleaning
The metal grease filters should be cleaned frequently in hot
detergent solution or washed in the dishwasher. Clean painted
hoods with hot soapy water. Stainless steel cleaner should
be used on stainless rangehoods. Abrasives and scouring
agents can scratch stainless steel finishes and should not be
used to clean finished surfaces.
Replacing the Lamps
Before replacing a lamp, turn off the lamp switch to prevent
an injury. To replace a halogen lamp (FIGURE 16), remove
the diffuser clips (T) on both ends of the stainless steel lamp
panel. Carefully slide the panel all the way to the right. Lower
the left end of the panel below the support flange (Z), then
remove the panel by sliding it back to the left.
Blower On/Off
Button ( M )
On/Off switch for
the blower. Move
the switch to "1"
to turn the blower
ON and to "0" to
turn it OFF.
Remove the lamp
by pressing the bulb
from the rear. Replace
the bulb. Replace
the lamp panel by
re ve rsi ng th es e
directions.