For best results, use no more than three 90° elbows. Make sure that
there is a minimum of 24" of straight duct between elbows if more than
one is used. Do not install two elbows together. If you must elbow right
away, do it as far away from the hood's exhaust opening as possible.
FIGURE 3FIGURE 2
PLAN THE INSTALLATION
The Matrix rangehood is designed to offer wide flexibility of installations. The
rangehood can be vented through the wall or ceiling (top or rear vented), or
installed in a ductless configuration. To vent through a wall behind the hood,
a 90° elbow is used and the chimney transition (included with this hood) is
placed on top of the hoods duct. When installed ductless, the rangehood
vents out of a grate on the top of the hood (included with this hood). Ductless
installations require a Charcoal Filter, available from your dealer.
WARNING! BEFORE MAKING ANY CUTS OR HOLES FOR INSTALLATION,
DETERMINE WHICH VENTING METHOD WILL BE USED AND CAREFULLY
CALCULATE ALL MEASUREMENTS.
WARNING
Because of the weight and size of the rangehood
canopy, two or more people are needed to move
and safely install the rangehood canopy.
Failure to properly lift rangehood could result in
damage to the product or personal injury.
PERSONAL INJURY HAZARD
FIGURE 1
A. CANOPY SECTION
B. MOUNTING BRACKETS WITH SCREWS
C. DUCTLESS GRILLE
D. REAR DUCTING CHIMNEY TRANSITION
E. CHIMNEY / VENT SCREWS
F. MOUNTING PLUGS
G. SAFETY SCREWS
H. GRILLE COVER
I. GRILLE COVER SCREWS
J. DAMPER
!
A
B
C
D
E
F
G
H
I
J
TOOLS NEEDED FOR INSTALLATION
• Saber Saw or Jig Saw
• Drill
• 1 1/4" Wood Drill Bit
• Scissors
• Pliers
• Phillips Screwdriver
• Flat Blade Screwdriver
• Wire Stripper or Utility Knife
• Metal Snips
• Measuring Tape or Ruler
• Level
• Pencil
• Caulking Gun
• Duct Tape
PARTS SUPPLIED FOR INSTALLATION
• 1 Hardware Package
• 1 Literature Package
PARTS NEEDED FOR INSTALLATION
• 2 Conduit Connectors
• Power Supply Cable
• 1 Wall or Roof Cap
• All Metal Ductwork
OPTIONAL ACCESSORIES AVAILABLE
Replacement Charcoal Filter
For non-vented installations only,
replace charcoal filter as needed
part # 6093034
Optional
Chimney Cover
For installations where rear venting / recirculating
are not possible or desired. When top venting you
can purchase
decorative stainless steel chimney
covers to place over duct work, part # 4472020 (lower
chimney) and part #4472013 (upper chimney).
WARNING
9 Feet Straight Duct
2 - 90˚ Elbows
Wall Cap
Total System
9.0 feet
10.0 feet
0.0 feet
19.0 feet
3.0 feet
5.0 feet
12.0 feet
0.0 feet
45˚ Elbow
90˚ Elbow
90˚ Flat Elbow
Wall Cap
CALCULATE THE DUCTRUN LENGTH
The ductrun should not exceed 35 equivalent feet if ducted with the required
minimum of 6" round duct. Calculate the length of the ductwork by adding
the equivalent feet in
FIGURE 2 for each piece of duct in the system. An
example is given in
FIGURE 3
.