Faber Matrix Ventilation Hood User Manual


 
Version 09/05 - Page 9
Cleaning
The stainless steel grease filters should be cleaned frequently in
hot detergent solution or washed in the dishwasher. Stainless
steel cleaner should be used on stainless rangehoods.
Abrasives and scouring agents can scratch stainless steel
finishes and should not be used to clean finished surfaces.
The inside of the ducting panels (FIGURE 12) should be
cleaned with a damp cloth and a neutral dish detergent. Do
not use wet sponges or cloths or jets of water; do not use
abrasive substances.
Grease Filter and Charcoal Filter Alarm Reset
To reset the metal grease filter alarm and the charcoal filter
saturation alarm, turn off the motor and lights. Press and
hold the speed 3 button for a minimum of 3 seconds until the
LED's start to flash.
USE AND CARE CONTINUED - MAINTENANCE
FIGURE 12
Charcoal Filter Information
The charcoal filters should be replaced (as indicated in FIGURE
9) when the S1 LED light flashes or at least every 4 - 6 months
depending on heavy usage. The alarm only comes on when the
motor is turned on.
To replace the charcoal filter, open the ducting panels, remove
the metal grease filters and remove the old charcoal filters and
replace with the new ones. Then replace the metal grease filters
and close the ducting panels.
Charcoal Filter Alarm Activation
The filter alarm has to be activated in order to use with ductless
installations which use the charcoal filters. The alarm can be
activated upon installation or at a later time. To activate or de-
activate the alarm turn off the motor and lights, and disconnect
the hood from the power source by disconnecting the main switch
located on the left side of the motor housing. Press and hold
the T1 (speed 1) button and while holding down the T1 button,
reconnect the power source. All 5 LED lights will then turn on
and within 3 seconds press and hold the T1 button (speed 1)
until the LED's on T1 (speed 1) and T4 (speed 4) flash to confirm
the chosen setting:
LED flashes twice - Charcoal filter saturation alarm ENABLED
LED flashes once - Charcoal filter saturation alarm DISABLED
Repeat the process if you want to change the chosen setting, ie if
the filter alarm is disabled, repeat the above paragraph to enable.
Once finished with the activation / de-activation, unplug and plug
in again the power source to return to normal hood function.
Replacing the Lamps
Remove the light cover (as indicated in FIGURE 13) by
removing the screws on the light bar. Remove the lights from
the housing and replace the lamp with a 20 W MR-11 halogen
lamp. Make sure that the two pins are properly inserted into
the lamp holder socket. Replace the light cover.
FIGURE 13
WIRING DIAGRAM
  
  
 

  
 

 





• This rangehood uses 20 watt halogen lamps.