Fisher & Paykel 60 Cooktop User Manual


 
6
750 mm
500 mm
105 mm
450 mm
Clearances
Installation clearances and protection of combustible surfaces shall comply with the current
local regulations eg. AG 601 (AS 5601) Gas Installations code. Installation shall comply with the
dimension in Fig. 1 bearing in mind that:
Overhead Clearances
In no case shall the clearance above the highest part of the cooker be less than 600 mm or, for
an overhead exhaust fan, 750 mm. AII other downward facing combustible surfaces less than
600 mm above the cooker surface shall be protected for the full width of the cooking surface in
accordance with the standards noted above. In no case shall the clearance be less than 450 mm.
Rear and Side Clearances
Where the distance from the periphery of the nearest burner to any vertical combustible surface
is less than 200 mm, the surface shall be protected in accordance with the standards to a height
of not less than 150 mm above the cooking surface for the full width or depth of the cooking
surface.
Where the distance from the periphery of the nearest burner to any horizontal combustible
surface is less than 200 mm, the horizontal surface shall be more than 10 mm below the surface
of the hob, or the horizontal surface requirement above.
Protection of combustible surfaces
The standards above specify that, where required, protection shall ensure that the surface
temperature of the combustible surface does not exceed 65°C above room temperature.
If you stand the cooker on a pedestal, make sure you provide safety measures to keep it in place.
Installation instructionsInstallation instructions
Cooker overall dimensions [mm]
height: min 900 - max 915
width: 600
depth: 600
Fig. 1 Dimensions and
distances from cooker