Fisher & Paykel CE365D Cooktop User Manual


 
12
Installation instructions
Additional electrical requirements
Electrical installation must be carried out only by a licensed electrician.
The cooktop MUST be connected to the proper electrical voltage and frequency as specified:
Model - CE365D Rated power - 8.4kW (6.5kW)
Required power supply - 240V~, 35A, 60Hz (208V~, 30.3A, 60Hz)
This appliance must be connected to a grounded, metallic permanent wiring system or a ground
connector should be connected to the ground terminal or wire lead on the cooktop.
This appliance is manufactured with a frame-connected, green or bare ground wire. Connect the
cooktop cable to the junction box through the CSA or UL-listed conduit connector. Complete
electrical connection according to local codes and ordinances.
Warning: improper connection of aluminum house wiring to copper leads can result in an
electrical hazard or fire. Use only connectors designed for joining copper to aluminum and
follow the manufacturer’s recommended procedure.
Connect the cooktop with copper wire only.
The flexible (4’) armored cable should be connected directly to the junction box.
Do not cut the conduit.
A CSA or UL-listed conduit must be provided at the junction box.
Do not ground to a gas pipe.
Do not have a fuse in the grounding or neutral circuit.
A time delay fuse or circuit breaker is recommended.
Connect directly to the fused disconnect (or circuit breaker box) through flexible, armored or
non-metallic sheathed, copper cable (with grounding wire).
If codes permit and a separate grounding wire is used, it is recommended that a qualified
electrician determine that the grounding path and wire gauge are in accordance with local
codes.