Fisher & Paykel CG122 Cooktop User Manual


 
10
Installation instructions
Dimensions and clearances - CG122 models
The installation shall comply with the dimensions and clearances in Fig. 1, bearing in mind the
following requirements:
The cooktop may be installed directly into existing cabinetry. The minimum required depth of
the countertop is 24” (610 mm).
When centring the cooktop in the cutout, make sure that the distance between the edge of the
cutout and the edge of the countertop is 2” 23/64 (60 mm) both in the front and the back.
When the cooktop is installed in the cutout, the distance between the edge of the cooktop and
the edge of the countertop must be 1” 31/32 (50 mm) both in the front and the back.
If the hole for the gas pipe is made in the wall, it must be located at least 11” 51/64 (300 mm)
below the underside of the countertop. If the hole for the gas pipe is made in the cabinet floor,
it must be located at least 3” 1/8 (79.2 mm) away from the wall.
The power supply cable supplied is 48” (1220 mm) long and has a three-prong grounded plug. It
must be plugged into a grounded power outlet, located within 36” (914.4 mm) of the right rear
corner of the cutout.
The cooktop MUST NOT be installed directly adjacent to side walls, tall cabinets, tall appliances
or other such vertical combustible surfaces. There MUST be a minimum side clearance of 4” (102
mm) from the edge of the cutout to such vertical combustible surfaces EITHER ON THE LEFT OR
THE RIGHT of the cutout. One side (left or right) MUST ALWAYS be kept clear.
The maximum overall depth of overhead cabinetry above the cooktop is 13” (330 mm).
The cabinet directly above the cooktop (minimum width 11” 13/32 (290 mm)) must be centred
with the cooktop and be at least 30” (762 mm) above the countertop. Other overhead cabinets
must be at least 18” (457 mm) above the countertop.
If an undercounter cabinet has a drawer, a 4” (102 mm) clearance from the top of the countertop
to the top of the drawer (or other obstruction) is required. The depth of the drawer may need to
be modified to avoid interfering with the gas pressure regulator.