Fisher & Paykel CG602 Cooktop User Manual


 
CONTROLS 3
IGNITION
ADJUSTING THE FLAME
FLAME FAILURE
Adjust
OFF
Choose the control knob for the burner you want to
use. Press down and turn the knob counter clockwise
to the High symbol.
All the ignitors will spark until the gas ignites on the
selected burner (see Figure 1).
The flame can be adjusted anywhere between the
High and Low symbol, do not regulate the flame
between High and Off.
Flame Failure is a safety device fitted to some models
(listed below). A metal probe behind the burner
generates electricity when a flame is present. After 5
seconds the metal probe gets hot enough to hold a
valve open and maintain the gas supply. If the flame
is blown out then the gas to the burner is cut off.
To operate the Flame Failure you need to hold the
burner knob down for 5 seconds after the burner has
ignited. Letting go too soon will extinguish the flame.
The Flame Failure models are
CG602F/CG602WF/CG602WFC & GC9002 series. If
you are unsure if you have a Flame Failure model, you
can look at the back of the burners and check there
are two probes (spark electrode and flame failure
probe), indicating a flame failure model.
Figure 1
599004KL_GC600_GC9002_USECARE 24/10/02 10:28 Page 4