Fisher & Paykel DD124P5 Dishwasher User Manual


 
23
US CA
User maintenance instructions
Cleaning the spray arm and filter plate
Ensure the DishDrawer® is cool before you start cleaning and follow the instructions for
removing the drain filter and spray arm.
1
Remove the basket carefully. Lift from the back
end first to prevent knocking the detergent
and rinse agent dispenser.
2
Lift the spray arm and shake any foreign material
out.
Rinse the spray arm clean under running water
and wipe with a damp cloth.
3
In the center of the filter plate there are two rings.
Hold the center ring still and turn the outer ring
counter-clockwise, about a 1/8 turn. This will
release the filter plate.
4
Lift the filter plate out.
When cleaning the underside of the filter plate,
take care handling the sharp outer edge to avoid
the risk of cuts.
Remove any foreign material, wash in hot soapy
water and rinse thoroughly in clean water. The
heater plate can be wiped with a damp cloth.
5
Replace the filter plate so it lies flat in the base of
the drawer ensuring the filter plate is fully locked
into position with the center ring.
6
To lock the filter plate into position, ensure the
lines align with each other (refer to the diagram
for the correct position). The filter plate must not
be able to move about freely.
7
Replace the spray arm back onto the impeller.
8
Replace the basket, lowering the front edge of the
basket into position first.
Note: Where there is broken crockery or glass in the
drawer, it must be carefully removed to prevent
damage to the DishDrawer®.
Correct locking position of filter
plate with motor assembly
(under spray arm)
a Outer ring
b Impeller
c Correct alignment marks
d Center ring
a
b
d
c
1
1
2
3
4