INSTALLATION
ATTENTION: This appliance can be installed and operated only in rooms that
are continuously ventilated according to UNI 7129/UNI 7131.
IMPORTANT: The installation must be carried out by professionally qualified
personnel following the manufacturer's instructions. Any maintenance on the
appliance must be performed with the appliance disconnected from the electrical
power supply and with the gas supply tap closed. The installation must be carried
out in compliance with the current regulations in the country in which the
appliance will be used.
Gas connection
For the connection of the appliance to the gas distribution system or a gas
cylinder, use the rigid metal pipe in copper or steel with relative fittings
compliant with the standard U
NI
-
CIG 7129 or the flexible hose in stainless steel
with continuous wall compliant with standard UNI-CIG 9891. The pressure
regulators used must be compliant with the standard UNI
-
CIG 7432.
Electrical connection
The electrical connection must be carried o
ut by a qualified technician according
to the manufacturer's instructions and in compliance with current local standards.
Make sure the voltage matches the value indicated on the technical data plate
visible, with the door open, on one of the side edges of the cavity. If the plug is
not easily accessible, the installer must provide an omni-polar switch with a
contact opening distance of at least 3 mm. The appliance is supplied with a
plugless cable. A normalized plug must be used, taking into consideration that:
YELLOW
-GREEN = EARTH
BLUE = NEUTRAL
BROWN = PHASE
The appliance is required by law to have an earth connection.
Do not use multiple sockets or extension cords.
25