Foster QC 11 Freezer User Manual


 
8
Hard Chill +-. This program is for specialist chilling only and is not recommended for normal use. (Cy3)
dbC = no iS1 = -6°C iS2 = 3°C iS3 = -18°C dbH = no
rS1 = -15°C rS2 = 2°C rS3 = -30°C HdS = 3°C
Pd1 = 1.1 hours Pd2 = 0.2 Pd3 = OFF
Hard Chill Temperature - For general purpose chilling using the food probe. (Cy4)
dbC = no iS1 = -6°C iS2 = 3°C iS3 = -18°C dbH = no
rS1 = -15°C rS2 = 2°C RS3 = -30°C HdS = 3°C
Pd1 = 1.1 hours Pd2 = 0.2 Pd3 = OFF
Function Menu
To access the cycle parameters Press and Hold the Set and Down buttons for 2 seconds.
The display will show “Prb”.
Prb: Probe Display.
Allows the probe temperatures to be displayed for ten seconds.
rPr: Displays temperature measured by the AIR probe.
Epr: Displays temperature measured by the EVAPORATOR probe.
IPr: Displays temperature measured by the FOOD probe.
Press SET to display the reading of the selected probe, press SET with the reading displayed returns to the probe
labels.
Probe Fault Identification.
rPF = AIR probe fault.
EPF = EVAPORATOR probe fault.
iPF = Food probe fault.
Pr1: User Parameters.
Includes all user accessible parameters. If no parameters are present in the menu “Pr2” will be displayed.
Pr2: Installer Parameters.
Includes all the instrument parameters (at installer level). It can only be accessed using the security code. On
entering the parameters it is possible to modify all parameters and add or remove parameters from “Pr1” (user
level) by pressing “SET” + “UP”. When a parameter is enabled at user level, LED 5 (Alarm LED) is on.
Fcy: Cycle Managent.
The Fcy menu contains the Cy1, Cy2, Cy3 and Cy4 sub menus. Each of the sub menus should be set to the
Standard Cycle Parameters as detailed on pages 6 and 7.
Sto: Cycle Length.
The “Sto” menu records the real length of a cycle and the real length of each single phase. It contains the
following sub menu:
tCy: Cycle Duration. tP1: First Phase Duration. tP2: Second Phase Duration. tP3: Third Phase Duration.
rtC: Clock Managent.
Real time clock parameters.
SEC: Seconds (00 to 59).
Min: Minutes (00 to 59).
Hou: Hours (1 to 24).
7dY: Day of the week (Mon = Monday. tue = Tuesday. Wed = Wednesday. Thu = Thursday. Fri = Friday. Sat =
Saturday. Sun: Sunday)
dAY: Day of the Month (1 to 31).
Mon: Number of the month (1 to 12).
YEA: Year (0 to 99).
Alr: Alarms Display.
This function displays any alarm messages.
Prt: Printer Management.
Contains the parameters for the management of the printer.