Franke Consumer Products FBI 482 XS RB Ventilation Hood User Manual


 
EN
1
1
11
ELECTRICAL CONNECTION
Connect both green ground wires (from exterior blower motor
and from 120-volt supply wiring) under the unused green ground
screw.
120-volt supply wiring:
• Connect 120-volt black supply wire to black hood liner wire
with a twist-on connector.
• Connect 120-volt supply white wire with to white hood liner
wire with a twist-on connector.
Exterior blower motor wiring:
• Connect the black blower motor wire to the blue hood liner
wire with a twist-on connector.
• Connect white blower motor wire to brown hood liner wire
with a twist-on connector.
Replace wiring box cover .
hood liner
wiring
green
ground
screw
green
ground
wires
power
supply
cable
exterior
blower
wiring
white
wires
white
wire
(from
blower)
brown wire
(from hood
liner)
blue wire
(from hood
liner)
black
wire
(from
blower)
twist-on
connector
black
wires
10.Insert the screw through the support and thread into the hood liner holes. Tighten screw se-
curely.
11.Reconnect the power and Reinstall filters.
12.Install the damper 10 ø 6” and fix the duct in position using sufficient pipe clamps (not sup-
plied).
10