Franke Consumer Products FKU 368 TC I Ventilation Hood User Manual


 
EN
1
1
11
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using a rigid 6” duct. (not supplied)
• Install the damper 10a ø 6”.
Fix the duct in position using sufficient pipe clamps.
10 a
ø 150
25
DUCTLESS VERSION AIR OUTLET
Fix the connection 15 to the frame using the 4 screws provided.
Fix the flange 10 to the lower opening of the connection 15.
• Connect the hood air outlet to the flange in the lower part of
the junction using a rigid ø 6” tube (not supplied).
15
10
Chimney assembly - Mounting the hood body
Position the upper chimney section and fix the upper part to the
frame using the 2 screws 12c provided.
Similarly, position the lower chimney section and fix the lower
part to the frame using the 2 screws 12c provided.
Before fixing the hood body to the frame:
Remove the grease filters from the hood body.
Remove any activated charcoal filters.
• From below, use the 4 screws 12f provided to fix the hood
body to the frame.
12c
12c
12f