Electrical connection
• Remove the cover from the Field Wiring Compartment with a
phillips screwdriver.
• Feed the Power Supply Cable through the electrical knockout.
Connect the Power Supply Cable to the range- hood cable. At-
tach the Power Supply Cable grounding lead to the green screw
provided. Attach the White lead of the power supply to the
White lead of the rangehood with a twist-on type wire connec-
tor. Attach the Black lead of the power supply to the Black
lead of the rangehood with a twist-on type wire connector.
Replace the cover.
Connect the control connector Cmd.
Connect the lights connector Lux.
• Place the connectors in the junction box 24 and close it using
the 2 screws 12e provided.
• Fix the junction box to the hood body using the 2 screws 12c
provided.
Power supply cable
Green
Ground
screw
Ground wire
24
12e
Cmd
12c
Lux