INSTALLATION
Wall drilling and bracket fixing
On the wall, draw:
a Vertical line up to the ceiling or upper limit, at the centre of the area in which the hood is
to be fitted;
a Horizontal line at a minimum of 1150 mm above the Cooker Top; .
As indicated, mark a reference point at 100 mm to the right of the vertical reference line.
Repeat this operation on the other side, checking that the two marks are level.
As indicated, mark a reference point at 390 mm above the horizontal reference line, and at
100 mm to the right of the vertical reference line.
Repeat this operation on the other side, checking that the two marks are level.
Drill at the points marked, using a ø 10 mm drill bit.
• Insert the plugs 11 into the holes.
11
12a
100 100
1150 390
1340
175
170
100 100