Franke Consumer Products FTU 3807 W Ventilation Hood User Manual


 
EN
2
4
24
Activated charcoal filter (Recirculation version)
• The filter is not washable and cannot be regenerated. It must be replaced when led S1
flashes or at least every 4 months. The alarm signal will only light up when the extractor
motor is switched on.
Alarm signal activation
• In Recirculation version Hoods, the Filter saturation alarm can be enabled on installation or
at a later date. Turn the Lights and the suction Motor off.
• Disconnect the Hood using the Main switch or the double-pole switch on the mains power
supply.
Restore the connection by pressing and holding T1.
Release the button. All five LEDs are turned on
Within 3 seconds press T1 until LEDs T1 and T4 flash in confirmation:
LED flashes twice - Activated charcoal filter saturation alarm ENABLED
LED flashes once - Activated charcoal filter saturation alarm DISABLED
REPLACING
Alarm signal reset
Turn the Lights and the suction Motor off.
• Press T3 for at least 4 seconds, until indicators T1 and T4 flash
to confirm.
Replacing the Filter
Open the lighting unit by pulling on the nocth
Remove the metal grease filters
• Remove the saturated activated carbon filter by releasing the
fixing hooks
Fit the new filter by hooking it into its seating
Replace the metal grease filters and the lighting unit.
Lighting
LIGHT REPLACEMENT
20 W halogen light.
Extract the lamp from the lamp holder by pulling gently.
• Replace with another of the same type, making sure that the
two pins are properly inserted in the lamp holder socket holes.