Frigidaire FHWC3660LS Ventilation Hood User Manual


 
5
GB
Electrical requirements
Itisthecustomer’sresponsibility:
• tocontactaqualiedelectricalinstaller.
• to assure that the electrical installation is
adequate and in conformance with National
Electrical Code, ANSI/NFPA 70 – latest edition*,
or CSA Standards C22.1-94, Canadian Electrical
Code, Part 1 and C22.2 No.0-M91-latest edition**
and all local codes and ordinances.
If codes permit and a separate ground wire is
used,itisrecommendedthataqualiedelectrician
determines that the ground path is adequate.
• Donotgroundtoagaspipe.
• Checkwithaqualiedelectricianifyouarenot
sure range hood is properly grounded.
• Do not have a fuse in the neutral or ground
circuit.
IMPORTANT
Save installation instructions for electrical
inspector’suse.
The range hood must be connected with copper
wire only.
The range hood should be connected directly
to the fused disconnect (or circuit breaker) box
through metal electrical conduit.
Wire sizes must conform to the requirements of
the National Electrical Code ANSI/NFPA 70 – latest
edition”, or CSA Standards C22.1-94, Canadian
Electrical Code Part 1 and C22.2 No.0-M91 – latest
edition** and all local codes and ordinances.
A U.L.- or C.S.A.-listed conduit connector must be
provided at each end of the power supply conduit (at
the range hood and at the junction box).
Copies of the standards listed may be obtained
from:
* National Fire Protection Association Batterymarch
Park Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
Power requirement:
120V~, 60Hz, 15 or 20A branch circuit
Intended use
• Yourrangehoodisintendedforexhaustoperation
only. This range hood is not recommended to be
used over indoor grills. Do not use it to exhaust
hazardous or explosive materials or vapors.
Parts supplied
No. Part Qty.
1
Range hood 1
2
Glass cover 1
3
Upper and lower
chimney
1
+
1
4
Upper bracket 1
5
Lower bracket 1
6
Collar 1
7
Recirculation kit
(optional
accessories)
-FHWRKT60LS
1
8
Bulb
20W, 120V~, GU10
(pre-assembled)
2
9
Bolt, rubber
washer, washer
4
sets
10
Long screw
(4mm x 32mm)
8
11
Wall plug 8
12
Short screw
(4mm x 12mm)
4
13
Allen key 1
14
Wood screw
(4mm x 50mm)
Short screw
(3.5mmx8mm)
4
15
Short screw
(3.5mmx8mm)
2
16
10’extension
chimney kit
(optional
accessories)
FHW10X60LS
1
17
Template
(stencilled)
Assembly template
(stencilled)
1
Important safety instructions