Replace filter O-rings Quarterly FR 3 Q4
©McDonald’s Corporation · Planned Maintenance Manual · Revised June 2009 Page 1 of 1
Frymaster Fryer Model BIELA14 and BIGLA30 – LOV
Quarterly FR 3 Q4
Why
To keep the fryer’s filter pump in working order
Time required
2 minutes to prepare 5 minutes to complete
Time of day
At open; the fryer must be cool
For 24-hour restaurants: During a low-volume period
when the fryer can be turned off
Hazard icons
Tools and supplies
O-rings for the filter
pump
Flat tip screwdriver
No-scratch pad
Procedure
1
Prepare fryer for procedure.
Check to make sure the fryer
is cool. This procedure should
be done only when the fryer is
cool and the filter pan is
empty.
2
Remove filter pan.
Pull the filter pan out of the
cabinet.
3
Replace O-ring.
Remove the O-ring from the
pan nozzle. Replace the O-
ring with a new O-ring. O-
rings can be purchased from
your local authorized servicer.
Use only the manufacturer’s
replacement O-ring. These
rings are manufactured spe-
cifically for use with hot
cooking oils. Generic O-rings
cannot be used for this pur-
pose.
4
Clean pickup tubes.
Clean the male and female
pickup tubes with a no-
scratch pad.
5
Reinstall filter pan.
Reinstall the pan into the
fryer cabinet.