Frymaster BIH1721 Fryer User Manual


 
EH1721 SERIES ELECTRIC FRYERS
CHAPTER 3: PREVENTATIVE MAINTENANCE
3-3
3.2 Periodic/Annual Maintenance
Frymaster recommends that the fryer be inspected annually by a Factory Authorized Service
Technician for the following checks and adjustments:
Inspect the cabinet inside and out, front and rear
for excessive oil build-up and/or oil migration.
Verify that the heating element wires are in good condition and that leads have no visible fraying
or insulation damage and that they are free of oil migration build-up.
Verify that heating elements are in good condition with no carbon/caramelized oil build-up.
Inspect the elements for signs of extensive dry-firing.
Verify that the tilt mechanism is working properly when lifting and lowering elements and that
the element wires are not binding and/or chafing.
Verify the heating-element amp-draw is within the allowed range as indicated on the appliance’s
rating plate.
Verify that the temperature and high-limit probes are properly connected, tightened and
functioning properly, and that the mounting hardware and probe guard is present and properly
installed.
Verify that component box and contactor box components (i.e. computer/controller, relays,
interface boards, transformers, contactors, etc.) are in good condition and free from oil migration
build-up and other debris.
Verify that component box and contactor box wiring connections are tight and that wiring is in
good condition.
Verify that all safety features (i.e. contactor shields, drain safety switches, reset switches, etc.)
are present and functioning properly.
Verify that the frypot is in good condition and free of leaks and that the frypot insulation is in
serviceable condition.
Verify that all wiring harnesses and connections are tight and in good condition.
Built-in Filtration:
Inspect all oil-return and drain lines for leaks and verify that all connections are tight.
Inspect the filter pan for leaks and cleanliness. If there is a large accumulation of crumbs in the
crumb basket, advise the owner/operator that the crumb basket should be emptied into a fireproof
container and cleaned daily.
Verify that all O-rings and seals (including those on quick-disconnect fittings) are present and in
good condition. Replace O-rings and seals if worn or damaged.