Frymaster CF Series Fryer User Manual


 
CF SERIES GAS FRYERS
CHAPTER 4: FILTRATION INSTRUCTIONS
4-7
DANGER
DO NOT operate the filter without the Power Shower in place. Hot oil will spray out
of the fryer and may cause injury.
3. Snap the Power Shower into the frypot.
Ensure the cleanout plugs are in place before
activating filter pump. After all oil has
drained from the pot, PULL the filter handle
(arrow) to start the pump and begin the
filtering process. There may be a slight delay
before the pump activates.
4. Oil will flow through the Power Shower,
rinsing debris from the frypot. Continue
circulating oil through filter for 5 minutes.
5. After the oil is filtered, close the drain valve
and allow the fryer to refill. When bubbles
appear in the oil, allow the filter to run 10 to
12 seconds longer to clear the lines and
prevent shortening from hardening in them,
then PUSH the filter handle to the OFF
position (arrow).
Oil-return
handle in
the open
position.
Oil-return
handle in
the closed
position.