Frymaster FPD65 Fryer User Manual


 
FRYMASTER FPD65 SERIES GAS FRYERS
CHAPTER 3: INSTALLATION
3-8
3.3.1 Specifications
3.3.1.1 Adjustments to Different Gas Types
Gas Adjustments
Gas Type
Natural LP
Manifold Pressure†
4" W.C.*/10 mbar* 11" W.C.*/27.5 mbar*
Orifice Diameter
Model Specific Model Specific
Burner Marking
None None
Pilot Marking
26N (P/N 810-0811) 16LP (P/N 810-2400)
* Gas pressure may vary per fryer model and altitude. Check the rating plate for specific
gas pressures.
NOTE: Outlet gas pressure must be adjusted strictly within the above requirements 5 to 10 minutes
after the appliance is operating.
For controls and adjustments, please refer to the "gas valve" illustration on page 3-9. (Pilot Flame
Adjustment: Turn the pilot adjustment screw clockwise/counter-clockwise until the desired flame-
volume is achieved.)
3.3.2 Gas Conversion Procedures
DANGER
This appliance was configured at the factory for a specific type of gas. Converting
from one gas type to another requires the installation of specific gas-conversion
components.
Switching to a different type of gas without installing the proper conversion
components may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A
GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED!
Conversion of this appliance from one type of gas to another should only be
performed by qualified, licensed, and authorized installation or service personnel, as
defined in Section 1.6 of this manual.