FRYMASTER HD1814 SERIES GAS FRYERS
CHAPTER 3: INSTALLATION
3-5
3.3.1 Specifications
3.3.1.1 Adjustments to Different Gas Types
Gas Adjustments
Gas Type
Natural LP
Manifold Pressure†
4" W.C.*/10 mbar* 11" W.C.*/27.5 mbar*
Orifice Diameter
Model Specific Model Specific
Burner Marking
None None
Pilot Marking
26N (P/N 810-0811) 16LP (P/N 810-2400)
* Gas pressure may vary per fryer model and altitude. Check the rating plate for specific
gas pressures.
NOTE: Outlet gas pressure must be adjusted strictly within the above requirements 5 to 10 minutes
after the appliance is operating.
For controls and adjustments, please refer to the "gas valve" illustration on page 3-6. (Pilot Flame
Adjustment: Turn the pilot adjustment screw clockwise/counter-clockwise until the desired flame-
volume is achieved.)
Ensure that CSA propane units air shutters are adjusted to a ¼” as shown.