CHAPTER 7: TROUBLESHOOTING
7-6
Fryer Troubleshooting (cont.)
7.2.6
Main burner malfunctions.
A. Main burner will not ignite; no gas is
present at main burner.
1. Check that float switch is not stuck
in the "down" position.
2. Check and reset the high-limit
switch.
3. The combination gas valve and/or
electronic ignition system may be
defective; Contact a FAS for
service.
B. Main burner flames are small and
appear lazy; shortening does not come
up to temperature quickly. Contact a
FAS for service.
C. Fryer will not reach setpoint
temperature and/or runs erratically.
1. Incorrect location or adjustment of
sensor probe. Contact a FAS for
service.
2. Defective temperature sensor. Contact
a FAS for service.
D. Fryer shortening temperature cannot be
controlled; fryer runs at high-limit
temperature. Possible causes are:
1. Defective operating thermostat.
Contact a FAS for service.
2. Defective temperature probe.
Contact a FAS for service.