Fujioh FDR-4200D Ventilation Hood User Manual


 
Conduit
Nut
Range
Hood
3. CONNECTING POWER SUPPLY WIRES
WARNING: Electrical wiring should be done by a qualified person(s) in
accordance with all-applicable codes and standards,
including fire-rated construction. An unqualified person
doing the work could result in fire, electric shock or injury.
This range hood uses 120V AC. Do not connect to another
voltage since fire, electric shock or damage could result.
1
Remove the nut from the conduit
connector at the end of power wiring.
WARNING: Be sure to switch
power OFF at service panel before
wiring.
2
Remove 1 screw fixing the wire box
cover, and detach the cover.
3
Connect the conduit through the
connecting hole of the body using the
nut previously removed.
4
Connect the electrical wires as follows:
Connect wires tightly and securely
using wire connectors (not supplied).
• Black to Black
• White to White
• Green to Green
5
Make sure that all wires are connected
properly and enclosed inside of the
wiring compartment, then replace the
wire box cover with the screw.
Conduit
Nut
Power
Wiring
Wire box
cover
Range
Hood
Conduit
Wire Connector
(not supplied)
Wire
(Conduit inside)
Wire (unit inside)