Fujioh FSR-3600 Ventilation Hood User Manual


 
10
CIRCUIT DIAGRAM
SPECIFICATIONS
120V
60Hz
Indicating Lamp
Lamp receptacle E26
(Lamp Max 60W)
Control Switch
AC125V 3A
Lock
Lock Release
Reset Key
Yellow
Yellow
Yellow
Red
60W 60W
Black
White
Black
Black
White
White
Black
Black
White
White
Green
Connector
Connector
Connector
Black
Red
Orange
Brown
Blue
Red
Orange
Brown
Blue
Orange
Brown
Blue
Capacitor
7µF 250VAC
Gray
Gray
Gray
Red
White
Model No.1U201361
Capacitor Running Induction Motor
Single-phase 120V 60Hz 100W
Ins.Class A 4 Poles
Main Coil 3
Main Coil 2
Main Coil 1
Thermal
Cutoffs
Auxiliary Coil
Refer to the following table.
NOTE:
FUJI INDUSTRIAL CO., LTD. has measured airflow under HVI-916 and noise levels under Japa-
nese Industrial Standard (JIS) C9603 items 8.8 and 8.9.
39
1.
2. , ,
3.
4. ,
6. , ,
5. ,
7. ,
In case of 7" Round Vertical Discharge
Voltage
(V)
Speed
Frequency
(Hz)
Power consumption
(W)
Air flow (CFM)
Noise level
(dB)
Hi
60
93
290
54
Med
60
69
230
47
120
Low
60
44
170
38
In case of 3-¼"×10" Vertical Discharge
Voltage
(V)
Speed
Frequency
(Hz)
Power consumption
(W)
Air flow (CFM)
Noise level
(dB)
Hi
60
93
250
54
Med
60
69
200
47
120
Low
60
44
140
38
In case of 3-¼"×10" Horizontal Discharge
Voltage
(V)
Speed
Frequency
(Hz)
Power consumption
(W)
Air flow (CFM)
Noise level
(dB)
Hi
60
93
270
54
Med
60
69
210
47
120
Low
60
44
150
38