Technical data (gas)
Burners: Normal burner
Full burning 6500 BTU (1.90 kW)
Low burning < 1400 BTU (0.41 kW)
High-intensity burner
Full burning 9500 BTU (2.8 kW)
Low burning < 1900 BTU (0.56 kW)
Gas connection:
R 1/2’’ union nut for R 1/2’’ bracket to DIN 1999,
conical-cylindrical
Technical data, gas
Technical data (electrical)
Rated consumption 0.8 W
Voltage AC 120 V
Frequency 60 Hz
Technical modifications reserved.
6. Technical data /Settings table
Countries US US
CA CA
Gas family Natural gas Propane gas
Gas type AE
Pressure 6” W.C. (1.5 kPa) 10” W.C. (2.5 kPa)
A burner, full burning 0.94 0.74
A burner, low burning 0.49 0.36
B burner, full burning 1.28 0.87
B burner, low burning 0.58 0.42
∑ Power 32 000 BTU (9.4 kW) 32 000 BTU (9.4 kW)
∑ Consumption 0.9 m
3
/h 680 g/h