Gaggenau KG 291 CA Cooktop User Manual


 
20
Technical data (gas)
Burners: Normal burner
Full burning 7,000 BTU (2.1 kW)
Low burning 700 BTU (0.175 kW)
Large burner
Full burning 14,500 BTU (4.2 kW)
Low burning 700 BTU (0.175 kW)
Wok burner
Full burning 17,000 BTU (5.0 kW)
Low burning 1,000 BTU (0.3 kW)
Total output 60,000 BTU (17.6 kW)
Gas connection: R 1/2’’ union nut for R 1/2’’
bracket to DIN 1999, conical-cylindrical
Settings table
Technical data (electrical)
Rated consumption 15 W
Voltage AC 120 V
Frequency 60 Hz
Technical modifications reserved.
13. Technical Data / Settings Table
Countries US US
CA CA
Gas family Natural gas Propane gas / L.P.G.
Pressure 6” W.C. (1.5 kPa) 10” W.C. (2.5 kPa)
Wok burner, full burning 1.70 1.10
Wok burner, low burning 0.59 0.41
Air gap adjustm. outer/inner [mm] 2 / 3 0 / 6
Large burner, full burning 1.48 1.03
Large burner, low burning 0.49 0.34
Air gap adjustm. outer/inner [mm] 0 / fixed 3 / fixed
Normal burner, full burning 1.01 0.49
Normal burner, low burning 0.69 0.34
Air gap adjustm. outer/inner [mm] 0 / fixed 3 / fixed
Total output (5 burners) 60,000 BTU (17.6 kW) 60,000 BTU (17.6 kW)