14
7.1 Technical data
Heating output:
Infrared grill: 3000 W
Dimensions (W
xHxD): Outer: 288 x 125 x 510 mm
11
5
/
16 x
4
15
/
16 x
20
1
/
16
”
Inner: 265 x 125 x 490 mm
10
7
/
16 x
4
15
/
16 x
19
5
/
16
”
Ordering spare parts:
Gridiron 355443
Grill tongs 292464
Grill brush 098263
Lava stones 291050
7.2 Important notes on assembly
The installing technician is responsible for
perfect functioning of the appliance at its
installation location. He must explain the operating
principle of the appliance to the user with
reference to the operating instructions. He must
draw the user's attention as to how to disconnect
the appliance from the mains whenever necessary.
Any damage caused by failure to observe these
instructions cannot be reimbursed.
Pay attention to the “Important notes" (Chapter 1).
Note: Several appliances can also be installed in
individual recesses, as long as a minimum
clearance of 40 mm (1
9
/
16
”) is kept to between the
appliances.
On installation, make sure that a minimum clearance
of 35 mm (1
3
/
8
”) from the wall trim or 50 mm (2”)
from the wall is observed (measured from the edge
of the appliance cutout). The building back wall
and building side walls must consist of non com-
bustible material or must be protected by no less
than
1
/
4
-inch-thick flame-retardant millboard
covered with no less than No. 28 MSG sheet steel,
0.015-inch-thick stainless steel, 0.024-inch-thick
aluminimum, or 0.020-inch-thick copper.
The distance from the bottom edge of the
appliance tub to the next combustible item of
furnishing must be at least 10 mm (
13
/
32
”).
Electrical connection
The appliance must only be connected by an
authorised electrician, paying attention to all
relevant codes.
Plug has to be conform with NEMA
CONFIGURATIONS FOR PLUGS AND
RECEPTACLES.
Plug must be rated not less than type 6-20 P
(2-pole 3-wire grounding).
Only a qualified electrician should install this
appliance.
The mains connecting cable must at least
correspond to the type SJTO 3x16 AWG 105°C.
You are advised to install a socket outlet (16 A fuse)
grounded in accordance with regulations
approximately 70 cm (27
1
/
2
”) above the floor behind
the appliance. This must still be accessible after
installation.
The grill's power rating is 3.0 kW. Pay attention to
the data on the rating plate. The appliance can be
connected with a plug.
If damaged, the mains cable must be replaced by a
special mains connecting cable. The mains
connecting cable must only be connected by the
manufacturer or the manufacturer's after-sales
service.
The factory reserves the right to make technical
modifications in the interest of progress!
7. Assembly instructions
VR 230-612 FD xxx
AC 208/220-240 V 60 Hz 2500/3000W
13A