Garland GIU 2.5 BI (BH/IN 2500) Cooktop User Manual


 
Part # 4521635 (03/04/08) Page 17
4. Not valid for WOK cookers. The parameters on the CPU
can now be changed! The unit temperature and the
ambient temperature must amount to 25°C (+/- 4°C) or
77°F (+/- 39°F). Press the key [ ; ]. On the console appears
the message “please conrm”. Press the key [ ; ] again. The
CU (RTCS) sensor will now be initialized on 25°C (77°F).
The following message now appears on the monitor:
save CU sensor : 25°C
5. Set the limit of the (mains) power current. (see mains
current parameters in this section):
N increase the limit of the mains current (+)
n decrease the limit of the mains current (-)
The following message appears on the monitor:
linecurrent limit= .......
6. Save the limit of the (mains) power current with the key [
]. On the console appears the message “please conrm”.
Press the key [ ] again. The following message appears
on the monitor:
save linecurrent limit: .......
7. Set the pan detector (see pan detector, Section 4):
T increase pan detector (+)
t decrease pan detector (-)
The following message appears on the monitor:
pan detector limit= .......
8. Save the pan detector with the key [ = ].On the console
appears the message “please conrm”. Press the key [ = ]
again. The following message appears on the monitor:
save pan detector limit: .......
9. By input [ -? ] the mode of adjustment will be left. The
following message appears on the monitor:
see you again!
10 The mode for adjustment has a time-out function.
After a 10 minute period, the mode of adjustment will
automatically reset.
The adjustments are now completed and it is not possible
to make any other adjustments at this point. If further
adjustments are necessary, you will be required to start from
the beginning again!
Technical information regarding the induction cooker is
also available in real-time, in the clients mode. The following
parameters listed below can be read:
Output on the hyperterminal:
1: KK:68 CU1:22 CU2:22 B:33 --- --- F:20080
1: KK:68 CU1:22 CU2:24 B:33 --- --- F:20080
1: KK:67 CU1:22 CU2:24 B:33 --- --- F:20080
1: KK:67 CU1:22 CU2:24 B:33 --- --- F:20080
Meaning:
1:KK:68 CU1:22 CU2:22 B:33 --- --- F:20080
CU Sensor 1 - Inside
Temperature of the coil
Active
Field
Heat Sink
Temperature
CU Sensor 2 - Outside
Temperature of the Coil
Error Message
Status Message
Frequency
Board
The internal cooling fan will be activated once the heat sink
temperature rises to 70°C (158°F).