To Replace or Adjust Door Latch Mechanism
1. Open oven doors.
2. Remove 2 pan head Phillips screws.
3. Lift door latch mechanism
up and out of door
assembly.
4. To adjust latch mechanism
, loosen lock nut
& and
adjust by tightening or loosening adjustment nut.
To Replace Convection Oven Motor Assembly
(Drawing Below)
1. Open doors and remove all oven racks.
2. Remove 4 #10 sheet metal screws (that secure air baffle)
and remove air baffle.
3. Remove six hex nut 1/4-20x7/16" (2A) and lock washers
(4A) from motor mounting studs.
4. Place a piece of cardboard on oven floor to protect from
scratching or chipping.
5. Pull entire motor assembly (1A) away from rear oven wall
into oven cavity and place on cardboard.
6. Disconnect wiring, be sure to note wire locations.
7. To reinstall reverse above procedure.
Convection Oven Motor