Garland MCO-GS-10M Convection Oven User Manual


 
23
Assembly
FILE NAME
JIT00012
7
6
2
1
3
8
5
4
5
9
1. Assemble
motor mount plate,
* insulation,
motor mount plate inner together by
fastening four flat head m.s. 1/4-20x2½"
into the four holes noted on the above drawings.
2. Secure each flat head m.s. 1/4-20x2½"
with a flat washer
and three hex nuts 1/4-20
.
3. Attach motor mounting plate to motor
. Insert the four flat head m.s. 1/4-20x2½"
through
the mounting tabs on motor
as shown. Secure with two hex nuts 1/4-20
.
4. Insert shaft of motor
through the hub of the blower wheel
. Space the blower wheel
¼" away from the inner motor mounting plate
.
5. Secure the blower wheel
to the shaft of the motor
by tightening the two set screws
on the blower wheel hub. Use a torque wrench and tighten to 180 inch pounds for proper
securing.
***** For warranty replacement we require that you use the motor assembly. Order motor
assembly part # CK1003090 - 2 Speed, 115 Vac, or CK1003091 2 Speed, 208/240 Vac (Export
or Special), CK1003092 - 1 Speed, 115,208,240 Vac.