Stovax RV66AVC Range User Manual


 
22
INSTALLATION INSTRUCTIONS
2. REMOVAL OF THE LOG GUARD
2.1 To remove the Log guard:
•LiftLogGuardclearofthesupportingbrackets
•Rotatetoclearthesidesofthedooropening.
Do not use appliance without the log guard in position.
3A. DOOR REMOVAL (RIVA)
(Tools required – None)
3a.1 To remove the door from the Riva MF:
•Openthedoorbyapproximately25mm
•Liftingthedoorfreeofthehingeblocksontheleftofthe
door
•Liethedoorfacedownonasoftflatsurface,toprotect
the paintwork and glass
3a.2 Take care to protect the top left hand corner of the door to
avoid damage to the paintwork.
3B. DOOR REMOVAL (RIVA AVANTI)
(Tools required - Large flat-blade screwdriver)
3b.1 To remove the door from the Riva Avanti:
 •Removethehingepin
Unscrewing the hinge pin from the body of the Riva and
pulling the pin out of the hinge blocks does this.
•Supporttheweightofthedoorbeforeremovingthepin
The door should be kept in the closed position when the
pin is removed.
•Releasethedoorcatchtoliftthedoorclearofthehinge
blocks
3b.2 Lie the door on a soft flat surface, to protect the glass and
paintwork.
3b.3 Replace the door in the reverse order from removal. Do not
hang the door from the catch only when replacing, as this
could damage the catch mechanism.
3b.4 Care should be taken to fully support the weight of the door
during the removal and replacement, as the door assembly
is heavy.
4. ASHPAN DOOR REMOVAL (RIVA)
(Tools required – 2.5mm A/F Hex socket key)
4.1 To remove the ashpan door from the appliance,
•Lowerthedoortoexposethehingefixingscrews(2each
hinge) Diagram 5
2
Fire Cement
PR7243
Adaptor supplied by flue
liner manufacturer.
3
1.6 If the Riva MF is installed on an unlined, masonry flue:
•Fitanon-combustibleclosureplatetolocatethefirst
section of single wall flue pipe from the Riva MF to the old
system
•Maketheconnectionaswithafluelinersystem
Do not connect the system into large voids that could exist
in older chimney systems. If this is the case consider using
a flue lining system to improve the Riva MF operation. See
diagram 16
PR7244
Closure Plate
Ridged Flue Pipe
4