Stovax RV66AVC Range User Manual


 
30
•SqueezeagenerousbeadoffreshStovaxThermicSeal
glue into the rope locating groove
•PressthenewStovaxropeintothelocatinggroove,
placing the joint in the middle of the lower edge of the
door
•Refitthedoorandclosethedoortoapplypressuretothe
new rope
•Leavetheapplianceclosedforatleast12hoursbefore
lighting the appliance and using at a low output for
approximately one day
11.2 Using the appliance with a damaged door seal can cause
dangerous fumes to enter the room, or the appliance to
over fire, resulting in damage.
12A. ADJUSTING DOOR CATCH - RIVA
12a.1 To maintain the safe use of your Riva, you may need to
adjust the door catch to ensure safe correct closing of the
door.
To Complete this operation:
•Openthemainfiredoortogiveaccesstothefixedpartof
the door catch as shown in diagram 7.
•Usinga2.5mmA/Fhexagonkeyloosenthe2fixing
screws, as shown in diagram 7
•Repositionthecatchblocktoachieveacorrectfit
This may need a trial and error approach to find the correct
position.
12a.2 If the door feels loose after correcting the catch operation
the door rope seal is worn and requires replacement, as
detailed in section 7.
Fixing Screws
3
Riva 66 Avanti see 3B
•Laythedoorfacedownonasoftflatsurface,toprotect
the paintwork and glass
•Removetheolddoorropesealandscrapeoldgluefrom
the locating groove
Clean with a dry cloth to remove dust and debris.
•Removetheglassclipfixingscrewswitha2.5A/F
hexagon key
The old glass can then be lifted clear of the door (Note how
the edge sealing tape is fixed).
•Disposeoftheoldglasssafely.
•Cleanandre-painttherearofthedoorifrequired
Clean the screws with light oil and coat with high
temperature anti-seize grease, this will aid future removal.
•Fittheedgesealingtapetothenewglassandplacethe
glass into position in the door
•Placethedoorframe/trimbackintopositionandrefix
with the cleaning fixing screws
Do not over tighten the clips as this could break the glass.
•SqueezeagenerousbeadoffreshStovaxThermicSeal
glue into the rope locating groove
Do not glue over the screw heads.
•PressthenewStovaxdoorsealingropeintothelocating
groove, placing the joint in the middle of the lower edge of
the door
•Refitthedoorontotheapplianceandclosethedoorto
apply pressure to new rope
Leave the appliance closed for at least 12 hours before
lighting the appliance and use at a low output for
approximately one day.
10.2 Fit only original Stovax ceramic glass, which is suitable to
use in high temperature applications.
10.3 Using the appliance with a damaged door glass could cause
dangerous fumes to enter the room, or the appliance to
over fire, resulting in damage.
11. FITTING A NEW DOOR SEAL
11.1 To maintain the safe use of your appliance you need to
replace damaged or worn door sealing rope. To complete
this operation:
•Removethedoorfromtheappliance,byopening25mm,
and lifting the door free of the hinge blocks
•Laythedoorfacedownonasoftflatsurface,toprotect
the paintwork and glass
•Removetheoldropeandscrapeoldgluefromthe
locating groove
Clean the locating groove with a clean dry cloth to remove
all old dust and debris.
MAINTENANCE and SERVICING