Stovax RVF40AVM Range User Manual


 
16
MAINTENANCE and SERVICING
8.3 Squeeze a generous bead of fresh Thermic Seal glue into
the rope locating groove.
Do not glue over the screw
h
eads.
P
ress the new rope into the locating groove, placing
the joint in the middle of the lower edge of the door.
8.4 Refit the door and close the door to apply pressure to new
rope. Leave the appliance closed for at least 6 hours before
l
ighting and using at a low output for approximately one
day.
8
.5 Using the Riva stove with a damaged door seal could cause
dangerous fumes to enter the room, or the appliance to
overfire, resulting in damage.
8.6 If you require help your local dealer will be able to
carry-out all of your service and maintenance requirements
for a reasonable cost.
(Tool required - 13mm A/F spanner)
9.1 To maintain the safe use of your Riva stove, you may need
to adjust the door catch to ensure safe correct closing of the
door. Complete this operating as follows
9.2 Open the door to give access to the fixed part of the door
catch as shown.
9.3 Using a 13mm A/F spanner loosen the locking nut holding
the catch block shown in diagram 11, and reposition to
a
chieve the correct fit. This may need a trial and error
approch to find the correct position.
9.4 If the door still feels loose after correcting the catch
operation, the door rope seal is worn and requires
r
eplacement, as detailed in section 8.
9.1 To maintain the safe use of your Riva stove, you may need
to adjust the door catch to ensure safe correct closing of the
door. Complete this operating as follows
9.2 Open the door to give access to the fixed part of the door
catch as shown.
9.3 Using a 4mm A/F hexagon head key (supplied) loosen the 2
fixing screws, as shown, and reposition the catch block to
achieve the correct fit. This may need a trial and error
approch to find the correct position.
9.4
If the door still feels loose after correcting the catch
operation, the door rope seal is worn and requires
replacement, as detailed in section 7 of the Users
Instructions.
9B. ADJUSTING DOOR CATCH
RIVA CUBE
PR7104
PR7103
Fixing Screw
4mm Hex Key
9A. ADJUSTING DOOR CATCH
RIVA AVANTI
PR7176
PR7177