GE 19 Refrigerator User Manual


 
23
Performance Data Sheet
Hotpoint
Filtration by GE SmartWater
TM
HXRT Cartridge
Performance Tested to NSF/ANSI*
(100% safety factors built in for unmetered usage)
Standard No. 42: Aesthetic Effects
Parameter USEPA Influent Effluent % Reduction
MCL Challenge Average Maximum Average Minimum
Chlorine 1.96 ppm 0.30 ppm 0.44 ppm 85 78
T & O ——
Particulate** 2296 62 116 97.3 94.9
* Tested using a flow rate of 0.5 gpm; pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 20° ± 2.5°C
** Measurement in Particles/ml of 10µ Particles
Operating Specifications
Capacity: certified for up to 250 gallons (946 L)
Pressure requirement: 40–120 psi (2.8–8.2 bar), non-shock
Temperature: 33°–100° F (0.6°–38° C)
Flow rate: 0.5 gpm (1.9 Lpm)
General Installation/Operation/Maintenance Requirements
Flush new cartridge at full flow for 60 seconds to purge out trapped air.
Replace cartridge when flow becomes too slow; at least every six months.
Special Notices
Installation instructions, parts and service availability, and standard warranty are included with the product when shipped.
This drinking water system must be maintained according to manufacturer’s instructions, including replacement of filter
cartridges.
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after
the system.
The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water.
Check for compliance with the state and local laws and regulations.
General Electric, Appliance Park, Louisville, KY 40225 © 1997 GE