23
Performance Data Sheet
Hotpoint
Filtration by GE SmartWater
TM
HXRT Cartridge
Performance Tested to NSF/ANSI*
(100% safety factors built in for unmetered usage)
Standard No. 42: Aesthetic Effects
Parameter USEPA Influent Effluent % Reduction
MCL Challenge Average Maximum Average Minimum
Chlorine — 1.96 ppm 0.30 ppm 0.44 ppm 85 78
T & O ——————
Particulate** — 2296 62 116 97.3 94.9
* Tested using a flow rate of 0.5 gpm; pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 20° ± 2.5°C
** Measurement in Particles/ml of 10µ Particles
Operating Specifications
■Capacity: certified for up to 250 gallons (946 L)
■Pressure requirement: 40–120 psi (2.8–8.2 bar), non-shock
■Temperature: 33°–100° F (0.6°–38° C)
■Flow rate: 0.5 gpm (1.9 Lpm)
General Installation/Operation/Maintenance Requirements
■Flush new cartridge at full flow for 60 seconds to purge out trapped air.
■Replace cartridge when flow becomes too slow; at least every six months.
Special Notices
■
Installation instructions, parts and service availability, and standard warranty are included with the product when shipped.
■This drinking water system must be maintained according to manufacturer’s instructions, including replacement of filter
cartridges.
■Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after
the system.
■
The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water.
■Check for compliance with the state and local laws and regulations.
General Electric, Appliance Park, Louisville, KY 40225 © 1997 GE