INSTALLATION INSTRUCTIONS
Step 12. Connect drain line
Follow all local codes and ordinances.
DRAIN LINE PREPARATION
1. All models are supplied with a pre-attached 78Ó
long corrugated drain hose. The molded end is
designed to fit 5/8Ó, 3/4Ó or 1Ó diameter connections
to the waste tee or disposer. Cut on premarked line
as required for your installation as illustrated in
Figure Q.
Note: DO NOT CUT CORRUGATED PORTION
OF HOSE.
Cutting Lines
1"
3/4"
5/8"
Do not cut corrugated
portion of hose
Cut Lines
Figure Q
If the location requires a longer drain hose, add up
to 42Ó length to the factory installed hose. Use 5/8Ó
inside diameter hose and thin wall copper coupler
to join the hose ends. Secure connection with
appropriate clamps (not supplied).
Note: TOTAL DRAIN HOSE LENGTH MUST
NOT EXCEED 10 FEET FOR PROPER DRAIN
OPERATION.
DRAIN LINE INSTALLATION
Connect drain line to waste tee or disposer as
previously outlined in “Prepare Drain Plumbing”
section of this manual. Refer to Figure S.
Secure connection using appropriate clamps (not
supplied).
Make sure drain hose is not kinked.
o
f
coun
t
er
t
op
32"
Min.
18"
Min.
20"
Min.
Under the sink connection
Hose may be fastened to
underside of countertop
Installation directly
through the floor
IMPORTANT: TO PREVENT POSSIBLE
DRAIN FROM SINK INTO DISHWASHER OR
SIPHONING OF DISHWASHER WATER,
DRAIN LINE MUST BE ROUTED AS
FOLLOWS:
MIN. 30Ó ABOVE THE FLOOR FOR UNDER
THE SINK CONNECTION.
MIN. 20Ó ABOVE THE FLOOR FOR
INSTAL-LATION DIRECTLY THROUGH THE
FLOOR.
20
Fig. R
Step 13. Connect power supply
Verify that power is turned off at source. If
power cord is used, plug it into the wall outlet and
go to Step 14.
If dishwasher is to be directly wired to house
wiring, continue with this step.
Remove junction box cover.
Secure the power supply cable to the back of the
junction box with a strain relief (not supplied).
Connect incoming wires to dishwasher wires using
wire nuts of appropriate size. Connect incoming
white to white wire, black to black wire and
incoming ground to green wire as shown in
Figure S. Replace the junction box cover.
If house wiring is not 2-wire as
shown in Figure S with a ground
wire, a ground must be provided by
the installer.
When house wiring is aluminum, be
sure to use UL/CSA. recognized anti-
oxidant compound and aluminum-to-copper
connectors.
CAUTION
WARNING
Check to be sure that wiring is not
pinched or in contact with the door
springs.
CAUTION
WARNING
Figure S
NOTE: Check that harness
leads are threaded through
small hole in bracket. Ground
White
Neutral
Black
Live