GE 255 Valve / 400 Series Water Dispenser User Manual


 
13
Control Valve
Figure 10 - Control Valve
5. Put into operation.
a. Open water supply valve slowly to full open position.
b. Carefully advance indicator knob COUNTERCLOCKWISE to center of
FAST RINSE/REFILL position and hold there until air check (Figure 10) fills
with water and water starts to flow through brine line into brine tank. Do not
run for more than two minutes.
c. Advance indicator knob COUNTERCLOCKWISE until arrow points to the
center of the BRINE/SLOW RINSE position.
d. With the conditioner in this position, check to see if water is being drawn
from the brine tank. The water level in the brine tank will recede very slowly.
Observe for at least three minutes. If the water level does not recede or
goes up, or if air enters the transparent air check chamber and the ball falls
and seats, reference Troubleshooting section.
e. Advance indicator knob COUNTERCLOCKWISE to CONDITIONED
WATER.
f. Run water from a nearby faucet until the water is clear and soft.
Brine Line
Female Elbow
Check Ball
Air Check
1018075 Rev I.fm Page 13 Tuesday, February 17, 2004 4:26 PM