GE 255 Valve / 400 Series Water Dispenser User Manual


 
14
400 Series Control Settings
440i Control
Figure 11
Programming
1. Set days of regeneration on skipper wheel (Figure 11).
Pull all skipper pins outward (away from control).
Rotate skipper wheel until day arrow points to current day or number 1.
Depress skipper pin(s) at day(s) for which regeneration is desired.
2. Set the time of day.
Grasp timer knob and pull outward.
Rotate in either direction until the timer arrow points to the actual time of
day.
Release timer knob.
Note: With the time of day properly set, the conditioner will regenerate at about
2:30 a.m. If you prefer to have the unit regenerate at an earlier or later time, simply
set current time-of-day accordingly (e.g., to have the unit regenerate at 4:30 a.m.—
two hours later—set the clock two hours earlier than the actual time of day.)
Note: The Timer Locking Pin should always be horizontal (Figure 11) during
operation.
Indicator Knob
Timer
Locking Pin
Time Arrow
Timer Knob
Day Arrow
Skipper Pins
Skipper Wheel
1018075 Rev I.fm Page 14 Tuesday, February 17, 2004 4:26 PM