GE JVM1540 Microwave Oven User Manual


 
– 21 –
Magnetron
WARNING: Prior to servicing the magnetron, be
certain the capacitor is discharged. Manually
discharge by placing an insulated-handle
screwdriver between the diode connection of the
capacitor and the oven chassis ground.
To remove the magnetron:
Remove the outer cover. (See 1. Outer Cover.)
Disconnect wiring to the magnetron.2.
Remove the 2 Phillips-head screws that attach 3.
the magnetron to the oven.
Vent Fan Motor Capacitor
The vent fan motor capacitor is located on the top
of the oven above the cooling fan.
To remove the vent fan motor capacitor:
Remove the outer cover. (See 1. Outer Cover.)
Disconnect wiring to the motor capacitor.2.
Remove the Phillips-head screw that attaches 3.
the motor capacitor to the oven.
Disconnect
Disconnect
View From Right Side
Disconnect
Disconnect
Disconnect
Cooling Fan Motor
The cooling fan and motor are located on the right
side of the microwave oven.
To remove the cooling fan and motor:
Remove the control panel assembly. (See 1. Control
Panel Assembly.)
Remove the outer cover. (See 2. Outer Cover.)
Disconnect the wiring to the cooling fan motor.3.
Remove the Phillips-head screw from the top, 4.
right corner of the microwave.
Disconnect
(Continued Next Page)